Click here to make tpub.com your Home Page

Page Title: AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM DUCTS DURING AC OPERATIONS (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
27.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to fan control switch OK.
Verify repair.
Blower operates.
(0012-56 blank).
REASON FOR QUESTION
AC condenser core not blocked or damaged.
AC compressor belts OK.
If AC system does not
Does AC system provide cold
provide cold air, fault has
AC heater/evaporator core not blocked or
not been corrected.
air through ducts?
damaged.
AC temperature control switch temperature
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
probe OK.
Heater cable OK.
AC cable OK.
Defrost cable OK.
AC compressor clutch OK.
AC harness wire 1154 OK.
Fault not corrected,
NO
Low pressure switch OK.
notify Supervisor.
AC harness wire 1156 OK.
AC harness wire 1158 OK.
High pressure switch OK.
YES
AC condenser motor solenoid OK.
AC condenser motor power wire OK.
AC condenser motor ground wire OK.
AC condenser motor OK.
Fault corrected.
AC condenser assembly harness black wire
OK.
AC harness wire 1155 OK.
AC condenser assembly harness green wire
OK.
AC condenser motor solenoid ground wire
OK.
Fan control switch OK.
Wire 1156 OK.
AC temperature control switch OK.
POSSIBLE PROBLEMS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
None
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0012-54

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business