Click here to make tpub.com your Home Page

Page Title: Personnel Locked Inside Container
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-4110-262-13&P
0006 00
Total loss of refrigerator from evaporation A rapid and total loss of refrigerant, as may result from a
broken refrigerant line, may displace air, causing possible suffocation. In the event of a sudden loss of
refrigerant, personnel should leave the IC interior immediately; leaving the door open to allow the
refrigerant to dissipate.
Other emergency situations may occur that do not represent a hazard to personnel. These situations
involve the potential loss or spoilage of cargo due to an inability of the system to maintain the required
interior temperature.
Personnel Locked Inside Container
The container door can be opened from the inside at any time, even if the handle is padlocked. To open
the door, turn the upper and lower hook and handle assemblies to a vertical position. Push the plunger
toward the outside. This will release the door latch and allow the door to swing open.
Failure To Maintain Storage Temperature
If the system is unable to maintain the preset interior temperature, see operator troubleshooting
procedures, Work Package 0007 00. Many problems may be solved by checking the following:
Is the power cord plugged into an appropriate power supply (see Work Package 0005 00)?
Is the setpoint correctly programmed into the RU control panel (see Work Package 0005 00)?
Are the container door and all other openings in the container closed?
More detailed troubleshooting procedures are outlined in Work Package 0007 00. If these steps do not
solve the problem,
1. Request assistance from your supervisor or
2. Replace the RU as described in Work Package 0023 00 with another RU known to be functioning
properly.
END OF WORK PACKAGE
0006 00630(4 3 lank)
0 00- / 0- B

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business