0011 00
CAUTION
Do not open the container door when the folding steps are deployed.
Failure to comply may result in damage to the equipment.
3. Open the door. Note any resistance in the movement of the freezer door latch or the two rotating
hook and handle assemblies. Inspect the seal around the full perimeter and note any wear,
deterioration, gaps or tears in the seal material.
4. Activate the inside freezer door release and the hook and handle assemblies. Note any resistance to
movement or malfunction.
5. Open the door to its fullest extent. Note resistance or binding in the door hinges.
6. Inspect the container interior surfaces. Note any breaks, cracks or dents in the sides, roof, base or
door. Note missing or damaged tie-down rings.
7. Inspect the interior light fixture, conduit, switch and pilot light. Note missing or damaged components.
Confirm that all components are firmly mounted on the container wall.
8. Close the door and engage the locks. Note any misalignment or gaps between the seal and
container.
9. Unfold the steps on both the front and rear of the container. Note any loose or damaged steps or any
for which movement is impaired. Fold the steps up after inspecting.
10. Examine the cargo restraint rails and note any bent or damaged areas. Visually confirm that all
mounting bolts are installed and appear tight.
END OF WORK PACKAGE