WARNING
Do not use a plastic container for mixing body filler and
hardener. Heat generated by mixed materials may melt
the container and cause burns. Mix the body filler and
hardener in a well-ventilated area. The vapor produced
is toxic. Avoid breathing vapors and avoid skin contact
with the mixture. If the mixture contacts the skin, flush
area with warm water and soap. Failure to comply may
cause serious injury or death to personnel.
WARNING
Isopropyl alcohol is toxic and flammable. Do not consume
internally and avoid inhaling vapors. Good, general
ventilation is normally adequate. Avoid all sources of
ignition. Failure to comply may result in serious injury to
personnel or death.
CAUTION
Do not pour repair chemicals or pastes into sinks, toilets, or garbage
containers. Material could set and clog drains or cause fire in containers
having flammable contents, oily rags, etc. Failure to comply may cause
damage to equipment.
1. Roughen the damaged panel surface with a disc sander to a radius of approximately four inches (10
cm) around the damaged area.
2. Fill all gouges and other depressions in the panel with body filler to the level of the panel surface.
Allow the body filler to harden at room temperature and sand it smooth. If the filler shrinks when
setting, repeat the application to raise the level of the filled area to the level of the panel surface.
0025 00-5