TM 10-4110-262-13&P
The process of removing all air and refrigerant from the refrigeration system.
Evacuate
This is usually done with a vacuum pump attached to the service valves of the
ADR-300 RU.
That section of the refrigerator that is inside the IC. The evaporator section
Evaporator
absorbs heat from the air inside the container. This cools the air to maintain the
Section
set point.
The high-pressure (condenser) side of the refrigeration system.
High-Side
One of the two components of the ADR-300 system. The IC includes the floor
Insulated
walls and roof and all attaching hardware as well as a removable shelf system
Container (IC)
inside the container.
The input terminal for a circuit breaker. The line side is energized by the source
Line Side
of power to the breaker.
The output terminal for a circuit breaker. The load side is energized when the
Load Side
breaker is closed and de-energized when the breaker is open.
The low-pressure (evaporator) side of the refrigeration system.
Low-Side
The printed circuit board housed in the RU electrical enclosure. The ADR-300
PC Board
PC board provides most of the control circuit signals to the ADR-300.
A small light that, when illuminated, indicates a specific system condition. The
Pilot Light
ADR-300 pilot light, mounted on the container exterior, near the door, indicates
that the interior light is turned on.
The electrical connector from which power is supplied to a system from an
Power Entry
external source.
Connector
Maintenance or service operations that are required on a regular or recurring
Preventive
basis to keep the ADR-300 system in good working order.
Maintenance
The process of removing all air and refrigerant from the evaporator side or the
Pump-down
entire refrigeration system. The evaporator side may be pumped-down by the
system compressor. The entire system is usually pumped-down with a vacuum
pump attached to the service valves of the ADR-300 RU.
The fluid contained in a refrigeration system that carries heat from the cold side
Refrigerant
to the hot side. The refrigerant in the ADR-300 is R404A.
Glossary-2