TM  10-4130-239-14 5-3. REFRIGERANT SYSTEM SERVICE -DISCHARGE  (CONT) . NOTE In accordance with Environmental Protection Agency regulations refrigerants cannot be discharged into the atmosphere. A refrigerant recovery& recycling unit must be used  whenever  discharging  the  refrigerant  system. Operation of the recovery/recycling unit must be by AUTHORIZED PERSONNEL ONLY 5. Connect and operate a recovery/recycling unit in accordance with the manufacturer’s instructions. 5-4. REFRIGERATION SYSTEM SERVICE - PURGING. This  task  covers:  Purging Equipment Condition Para Condition  Description 2-8 Engine  stopped. Tool Kit, Service 4-15 Housing removed. 5-3 System  discharged. Materials/Parts: Dry nitrogen, item 11, Appendix E Tools Refrigeration, item 5, Appendix B Nitrogen Regulator, item 8, Appendix B 5-6 Change  1