TM   10-4130-239-14 5-15. HIGH PRESSURE SWITCH REPLACEMENT (CONT) 3. Cut three tie wraps attaching refrigerant line to wiring harness. WARNING To prevent electric shock, make sure power is disconnected from 12 VOLT INPUT FOR STARTING connection before performing this procedure. 4. Tag three wires from switch. Remove two screws and three wires. 5. Remove three bracket mounting screws and three flatwashers. 6.  Remove  mounting  bracket  from  switch. 7. Remove high pressure switch and refrigerant line. 1. Install high pressure switch and refrigerant line in mounting bracket. 2. Install mounting bracket, three mounting screws, and three flatwashers. Change 2    5-31