TM  10-4130-239-14 5-19. EXPANSION VALVE REPLACEMENT  (CONT) 2. 3. 4. 5. 6. Loosen expansion valve bulb clamps (2) and carefully slide clamps free of expansion valve bulb from suction line. Install  refrigeration  charging  manifold  and  manifold  hoses  (para 5-3, 1 thru 5). Start engine (para 2-8b) and observe Insert the expansion valve bulb in a low pressure gauge. cup of ice. NOTE when  refrigerant Engine  will  automatically  stop pressure drops below 24 psi (165 kN/m2). Hold toggle switch S-3 in START position to prevent engine from stopping during test. 5-40