TM-5-4120-339-14 Air Conditioner Vertical Compact 9 000 BTU/HR 208 Volts 3-Phase 50/60 HZ Tierany Model TM9KV-208-3-60 Manual
Next
SECTION II. MAINTENANCE ALLOCATION CHART - continued - TM-5-4120-339-140129
TM 5-4120-339-14
SECTION II. MAINTENANCE ALLOCATION CHART
FOR
TM9KV-208-3-60
(1)
(2)
(3)
(4)
(5)
(6)
MAINTENANCE LEVEL
GROUP
MAINTENANCE
TOOLS AND
NUMBER
COMPONENT/ASSEMBLY
FUNCTION
C
O
F
H
D
EQUIPMENT
REMARKS
01
PANELS, COVERS AND
GRILLES
0101
PANELS
Inspect
0.5
Repair
1.0
Replace
0.5
0102
COVERS
Inspect
0.5
Repair
1.0
Replace
0.5
0103
GRILLES
Inspect
0.5
Adjust
0.1
Repair
1.0
Replace
0.5
0104
AIR FILTER
Inspect
0.2
Service
0.5
Replace
0.2
0105
MIST ELIMINATOR
Inspect
0.75
Service
0.75
Replace
1.0
02
FAN MOTOR & FANS
0201
IMPELLER FANS
Inspect
1.5
Repair
0.5
Replace
1.75
0202
FAN MOTOR
Inspect
1.5
Test
0.5
Repair
2.5
Replace
1.75
03
HEATING SYSTEM
0301
HEATING ELEMENTS
Inspect
0.75
Test
0.5
Replace
2.5
04
ELECTRICAL SYSTEM
0401
CONTROL BOX
Inspect
1.5
Repair
2.5
Replace
3.2
0402
SWITCHES
Inspect
1.1
Test
0.5
Replace
1.5
0403
THERMOSTAT
Inspect
1.5
Test
0.5
Replace
1.75