Figure 1-3. Refrigerant Schematic
Up
TM-5-4120-347-14 Air Conditioner Horizontal Compact 9 000 BTU/HR 208 Volt 3 Phase 60 Hertz Manual
Next
Chapter 2. OPERATING INSTRUCTIONS - TM-5-4120-347-140023
TM5-4120-347-14
The low pressure switch (2), the high pressure switch (14) and the pressure relief valve (13) are
provided to protect the unit from damage due to pressure extremes.
a. When the MODE SELECTOR is set for HIGH heat, all heating elements, located behind the evaporator
coil are energized. These elements are protected from overheating by a thermal cutout switch. Half of the
elements are thermostatically controlled by the TEMPERATURE SELECTOR, and remaining half are on all of
the time. When set for LOW, only the thermostatically controlled elements are energized.
b. The two speed fan can be set for either HIGH or LOW operation during heating