TM9 4120-423-14&P
1
One of more of the following cables:
Remote Control Cable (18876) 11455976-1
Remote Control Cable (18876) 11455976-2
Remote Control Cable (18876) 11455977-1
Remote Control Cable (18876) 11455977-1
Remote Control Cable (18876) 61455977-2
NOTE
A part number 11455976-1 or -2 cable must be used if only one cable is used. No cable
is required if remote control is installed in unit.
2
A power input cable with a plug on the air conditioner end suitable for attachment to an
MS3102R22-22P connector. The Patriot installation uses (18876) 11453295 power cable.
3
Installation hardware and grounding strap. The Patriot installation uses the following:
8 each (18876) 11447172-1 Flat Washers
16 each (18876) 11447981 Resilient Mounts
16 each (18876) 11447173 Flat Washers
8 each (18876) 11447172-2 Flat Washers
8 each (96906) MS35307-338 Hex Head Screws
4 each (18876) 11455133 Grounding Straps
4 each (96906) MS51958-97 Screws
4 each (96906) MS35335-62 Lock Washers
4 each (96906) MS21044C5 Self Locking Nuts
4
Condensate drain items may be required. If condensate drain water from the port(s) located in
the lower side panels of the evaporator assembly casing is objectionable, or creates a hazard, it
must be piped to a safe disposal location. The air conditioner is equipped with two 1/4-18 N.P.T.
drain connections. The air conditioner is shipped from the factory with both of these ports
plugged. The plugs must be removed prior to operation.
UNLOADING, UNPACKING, AND INSTALLATION
CAUTION
Use care in handling to avoid damage to the air conditioner. If an overhead lifting device
must be used, use an appropriate sling so that the weight of the unit is borne by the base
of the shipping container.
The air conditioner is packaged in a container designed for shipment and handling with the cabinet in an
upright position. The base of the container is constructed as a shipping pallet with provisions for the
insertion of the forks on materials handling equipment.