INSTALLATION
NOTE
If a complete factory assembled hose assembly is installed, it is not necessary to evacuate
and charge the Refrigerant R-22 system, if the half couplings closed properly and the
charge was not lost.
1
Position the new hose assembly in the air conditioner.
2
Using wrench, connect the condenser end hose fitting to half coupling at condenser fan motor
mounting bracket.
3
Using wrench, connect the evaporator end hose fitting to half coupling at access opening in
evaporator assembly.
4
Secure hoses to compressor junction box with two joined tie down straps.
END OF TASK