TM 9-4120-428-14
0012 00
TROUBLESHOOTING PROCEDURE
CONTAMINATED REFRIGERANT.
SYMPTOM
The refrigerant is contaminated.
MALFUNCTION
The refrigerant is contaminated.
CORRECTIVE ACTION
The refrigerant is contaminated if the sight glass appears yellow after the
compressor has run for about an hour, instead of green. Replace the dehydrator
if necessary. (WP 0075 00).
TROUBLESHOOTING PROCEDURE
AIR CONDITIONER NOISY DURING OPERATION.
SYMPTOM
The air conditioner remains noisy during operation.
MALFUNCTION
The expansion valve is defective.
CORRECTIVE ACTION
Check the expansion valve and replace if defective. (WP 0077 00).
The quench valve is defective.
CORRECTIVE ACTION
Check the quench valve and replace if defective. (WP 0078 00).
The compressor is making noise internally and is loosely mounted.
CORRECTIVE ACTION
If necessary, tighten the loose mounting and replace the compressor if defective.
END OF WORK PACKAGE