DRAFT
TB 9-2320-279-13-1
OPERATOR'S PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) -
Continued
Table 2-2.
Operator's Preventive Maintenance Checks and Services (Weekly) (Continued)
Location
Item
Not Fully Mission
Interval
Item to
Procedure
No.
Capable if:
Check/Service
HEMAC122
(a) Check AC evaporator core (1) for debris,
5
Weekly
AC Heater/
dirt, damage, and oil residue.
Evaporator and
Drain Hoses
(b) Check two AC evaporator drain hoses (2)
underneath cab. Notify Field Level
Maintenance if drain hoses are clogged
or kinked.
END OF WORK PACKAGE