DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE IN ALL SPEEDS
(LOW, MEDIUM, AND HIGH) - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
VISUAL INSPECTION
(1) Turn engine start switch ON (TM 9-2320-279-10).
(2) Turn fan control switch to low, medium, and high
speed positions (WP 0004). Verify AC heater/
evaporator blower operation in all positions.
(a) If AC heater/evaporator blower does not
operate in all positions, go to Step 3 of this fault.
(b) If AC heater/evaporator blower operates at all
positions, turn engine start switch OFF and go
to Step 15 of this fault.
VISUAL INSPECTION
(1) If OFF, turn engine start switch ON
(TM 9-2320-279-10).
(2) Turn fan control switch to low, medium, and high
speed positions (WP 0004). Verify AC heater/
evaporator blower operation in all positions.
(a) If AC heater/evaporator blower does not
operate in at least one switch position, go to
work package 0010 (AC Heater/Evaporator
Blower Does Not Operate).
(b) If AC heater/evaporator blower operates in at
least one fan control switch position, go to
Step 4 of this fault.
HEMAC130
0011-5
|