TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2.
KNOWN INFO
TEST OPTIONS
Power to fan control switch OK.
Visual inspection.
Blower operates.
REASON FOR QUESTION
AC condenser core not blocked or damaged.
Are AC compressor belts
If AC compressor belts are
tight and free from damage?
POSSIBLE PROBLEMS
missing, loose, or
damaged, AC compressor
AC compressor belts loose or damaged.
will not operate properly.
AC heater/evaporator core blocked or
damaged.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC temperature control switch temperature
probe damaged or installed incorrectly.
Heater cable faulty.
AC cable faulty.
Replace or tighten
Defrost cable faulty.
AC compressor belts
NO
as required
AC compressor clutch faulty.
(WP 0022). Verify
AC harness wire 1154 faulty.
repair, go to Step 27
High pressure switch faulty.
of this fault.
YES
AC harness wire 1156 faulty.
AC harness wire 1158 faulty.
Low pressure switch faulty.
AC condenser motor solenoid faulty.
AC condenser motor power wire faulty.
AC condenser motor ground wire faulty.
AC condenser motor faulty.
AC condenser assembly harness black wire
faulty.
AC harness wire 1155 faulty.
AC condenser assembly harness green wire
faulty.
AC condenser motor solenoid ground wire
faulty.
Fan control switch faulty.
Wire 1156 faulty.
AC temperature control switch faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0012-4
|