DRAFT
TB 9-2320-279-13-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
14.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to fan control switch OK.
Continuity test.
Blower operates.
AC condenser core not blocked or damaged.
REASON FOR QUESTION
AC compressor belts OK.
Is continuity measured
If continuity is measured, AC
AC condenser motor solenoid OK.
harness wire 1158 is
across high pressure switch?
AC condenser motor power wire OK.
faulty. If not, high
pressure switch is faulty.
AC condenser motor ground wire OK.
AC condenser motor OK.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC condenser assembly harness black wire
OK.
AC harness wire 1155 OK.
AC condenser assembly harness green wire
Replace high
OK.
pressure switch
NO
(WP 0039). Verify
AC condenser motor solenoid ground wire
repair, go to Step 27
OK.
of this fault.
Fan control switch OK.
Wire 1156 OK.
AC temperature control switch OK.
YES
AC heater/evaporator core not blocked or
damaged.
Repair AC harness wire 1158
AC temperature control switch temperature
(see Appendix A) or replace
probe OK.
AC wiring harness
Heater cable OK.
(WP 0046). Verify repair, go
to Step 27 of this fault.
AC cable OK.
Defrost cable OK.
AC compressor clutch OK.
AC harness wire 1154 OK.
Low pressure switch OK.
AC harness wire 1156 OK.
POSSIBLE PROBLEMS
AC harness wire 1158 faulty.
High pressure switch faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0012-28
|