DRAFT
TB 9-2320-279-13-1
AC COMPRESSOR DOES NOT SHUT OFF OR CYCLES CONSTANTLY - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
14.
KNOWN INFO
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Read WARNING on
TEST OPTIONS
AC heater/evaporator blower operates.
Verify repair.
(0014-18 blank).
AC compressor operates.
AC condenser core not blocked or damaged.
REASON FOR QUESTION
AC compressor belts OK.
If AC compressor does not
Does AC compressor operate
AC temperature control switch temperature
shut off or is cycling
probe OK.
correctly?
constantly, fault has not
AC condenser motor solenoid OK.
been corrected.
AC condenser motor red wire OK.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
AC condenser motor ground wire OK.
AC condenser motor OK.
AC condenser assembly harness black wire
OK.
AC harness wire 1155 OK.
Fault not corrected,
NO
AC harness wire 1156 OK.
notify Supervisor.
AC condenser assembly harness green wire
OK.
YES
AC condenser motor solenoid ground wire
OK.
POSSIBLE PROBLEMS
Fault corrected.
None
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0014-16
|