TB 9-2320-279-13-1
AC ALTERNATOR AND PULLEY REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
HEMAC001
6. Install two wires (12 and 13) on terminal (14) with lockwasher (11) and nut (10).
7. Install wire (8) on terminal (9) with lockwasher (7) and nut (6).
8. Install two wires (3 and 4) on terminal (5) with lockwasher (2) and nut (1).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
9. Apply electrical sealant to wires and mounting hardware on three terminals (5, 9, and 14).
FOLLOW-ON MAINTENANCE
1. Install AC alternator drive belts (WP 0019).
2. Install left splash guard (TM 9-2320-279-20).
3. Connect batteries (TM 9-2320-279-20).
END OF WORK PACKAGE