DRAFT
TB 9-2320-279-13-1
AC HOSES REPLACEMENT - Continued
HOSE ASSEMBLY #8 2521 INSTALLATION
HEMAC107
NOTE
Refer to Appendix A, Figure A-2, for routing and location of AC hoses.
Install cable ties as required.
Route AC hose as noted prior to removal.
Ensure preformed packings are in place in AC hose prior to installation.
1. Install preformed packing (18) and hose 2521 (1) on compressor (19). Torque hose 2521 (1) to
15-18 ft-lbs. (20-24 Nm).
2. Install hose 2521 (1) in cushion clip (15).
NOTE
Install cushion clips as noted prior to removal.
3. Install cushion clip (16) and cushion clip (15) on cushion clip (17) with screw (14) and locknut (13).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -