DRAFT
TB 9-2320-279-13-1
AC TEMPERATURE CONTROL SWITCH REPLACEMENT - Continued
REMOVAL
HEMAC045
NOTE
Fan control switch needs to be removed from center cover to access temperature control
switch.
1. Loosen two screws (1) and remove knob (2) from fan control switch (3).
NOTE
Note position of fan control switch prior to removal to ensure proper installation.
2. Remove nut (4) and fan control switch (3) from center cover (5).
HEMAC042
CAUTION
Remove temperature probe slowly from heater/evaporator. Failure to comply may
result in damage to temperature probe.
3. Remove temperature probe (6) from heater/evaporator (7).
0044-2
|