DRAFT
TB 9-2320-364-13&P-1
AC CONDENSER FAN MOTOR REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PLSAC016
CAUTION
Fan needs to be centered on fan motor shaft. Failure to comply may result in fan
blades hitting condenser when fan motor is running causing damage to equipment.
NOTE
Install fan on motor shaft as noted prior to removal.
5. Install fan (11) on fan motor (12) and tighten setscrew (10).
6. Install grille (9) on condenser (5) with five washers (8), lockwashers (7), and screws (6).
7. Install 1435 wire (4) on condenser (5) with washer (3), lockwasher (2), and screw (1).
FOLLOW-ON MAINTENANCE
1. Connect batteries (TM 9-2320-364-20).
END OF WORK PACKAGE
0025-5/(0025-6 blank)
|