DRAFT
TB 9-2320-364-13&P-1
AC TEMPERATURE CONTROL SWITCH REPLACEMENT - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PLSAC086
CAUTION
Do not puncture temperature probe. Failure to comply will cause gas in tube to leak
out.
Install temperature probe slowly into heater/evaporator. Failure to comply may
result in damage to temperature probe.
NOTE
Temperature control switch temperature probe is installed correctly when it is inserted into
the AC evaporator core until it touches the bottom of the insertion hole.
8. Install temperature probe (6) into heater/evaporator (7).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -