b. Recovery.
WARNING
Use care to prevent refrigerant from touching skin or eyes. Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye tissues. Serious injury or blindness may result if you
come in contact with liquid refrigerant.
Refrigerant R-134A air conditioning systems should not be pressure tested or leak tested with
compressed air. Combustible mixtures of air and R-134A may form, resulting in a fire or explosion,
which could cause personnel injury or death.
NOTE
Service valves are located on compressor.
1.
Remove cap (1) from service valve (2).
2.
Remove cap (3) from service valve (4).
3.
Close two recovery/recycling station hand valves (5 and 6).