TM 10-4110-262-13&P
0005 00
WARNING
For ADR-300 systems that will be airlifted, the hook and handle
assemblies should be left unlocked, using only the main door handle to
hold the door closed. This will allow pressure relief, if necessary during
flight. Failure to comply may cause serious injury or death to personnel.
Failure to comply may also cause equipment to implode or explode
causing hazard to the aircraft.
4.
Lock the cargo door and confirm the seal is satisfactory.
5.
Confirm that the drain plug, located under the door on the front face of the IC, is installed.
6.
As near as possible to the departure time, shut down the RU and disconnect the power cord from
the source of power.
7.
Move the container as described previously in this work package.
Drain Plug
If the ADR-300 is to be moved in a non-operational condition:
1. Turn off interior light.
2. Shut down the RU and disconnect the power supply cord from the RU connector.
3. Clean the container interior as described in Work Package 0017 00.
4. Restrain all loose items inside the container to the restraint rings on the floor of the IC.
5. Close and lock the cargo door.
6. Move the container as described previously in this work package.
0005 00-17
|