TM 10-4110-262-13&P
0005 00
NOTE
Do not block drain. Do not lock back-ups.
6. The container base interface with the aircraft cargo systems will be subject to the same reuse
inspection criteria as the HCU-6/E pallet. For ground handling and normal aircraft loading, 463L
compatible MHE is needed.
7. Any hazardous materials and components carried inside the container must have separate approval
for air transport in accordance with AFJMAN 24-204 / TM 38-250 / NAVSUP PUB 505 / MCO
P4030.19F / DLAM 4145.3. This direction is not to be considered approval for shipment of hazardous
materials. The servicing aerial port can assist in this regard.
Additionally, the container is approved for any pallet position in a C-130. During internal air transport, the
container door hook and handle assemblies (upper and lower) should be turned to the vertical (unlocked)
position. This allows the door to flex in the event of a rapid decompression, thus relieving pressure inside
the container.
LONG TERM STORAGE
If the ADR-300 will be unused for an indefinite period, take the following steps to preserve the system:
1. Elevate the container Support the container on at least three 4 x 4-in. beams. These should be
evenly spaced across the width of the container. This allows air circulation under the container and
prevents moisture accumulation and corrosion.
NOTE
We recommend a slight slope for drainage.
2. Wash the container interior and exterior as described in Work Package 0014 00. Allow the container
interior to dry thoroughly before closing it for storage.
END OF WORK PACKAGE
0005 00-21/(22 Blank)
|