4-29. STARTER PANEL ASSEMBLY REPLACEMENT (CONT)
To prevent electric shock, make sure power is disconnected from 12
VOLT INPUT FOR STARTING connection before performing this
procedure.
10. Remove starter cable mounting clamp bolt from blower housing.
Remove starter cable mounting clamp from starter cable.
11. Remove starter cable mounting nut, and flatwasher, from switch S7.
Remove starter cable
1.
Install starter cable on switch S7. Install flatwasher, lockwasher, and starter cable
mounting nut.
2. Install starter cable mounting clamp on starter cable. Install starter cable mounting
clamp and bolt on blower housing.
3. Install starter cable on starter. Install internal toothed washer and cable nut on starter.
4-58 Change 2
|