TM 10-4130-239-14
5-24.
EVAPORATOR REPLACEMENT (CONT)
1.
2.
3.
Cut tie wraps holding insulation on expansion valve
Remove two clamps from expansion valve bulb and refrigerant line.
Move bulb aside.
Remove evaporator pipe fitting from low pressure switch tee
fitting.
bulb.
5-55
|