TM  10-4130-239-14 6-2. CYLINDER BLOCK ASSEMBLY REPAIR  (CONT) WARNING l Solvent may cause toxic fumes. To  prevent personal  injury,  work  only  in  well-ventilated area. DO NOT breathe fumes for a long time. l Solvent is flammable. To prevent fire or explosion, DO NOT bring open flame or sparks near solvent. 3. Using solvent, clean cylinders to remove carbon buildup or foreign matter. 4. Using solvent, clean carbon buildup from piston and grooves. 5. Install new piston ring on top ring groove of piston. 6. Check remaining space in groove. If space is 0.007 in. (0.18 mm) or greater, remove piston ring and replace piston. 7. Repeat steps 4 through 6 for left cylinder. 8. Obtain right connecting rod assembly. Check  crankpin  bearing size. If greater than 1.627 in. (41.33 mm), discard connecting rod  assembly. 6-8