Figure 4-2.3. c.   Follow   procedure   outlined   in   paragraph   4-37 and  test  motor. d.  lf  tiny  deficiency  is  indicated.  remove  screws and   terminal   box   cover   and   check   for   damaged wiring or   loose connections. Repair   damaged wiring   and   tighten   loose   connections.   If   this   does not   correct   the   trouble.   report   the   conditions   to direct   support   maintenance. e.  Install  terninal  box  cover  and  screws.  Connect electrical  connector.  Refer  to  paragraph  4-21  and install  housing  rear  top  cover. 4-61.   Compressor   Capacitors   and   Relay a.  General.   Single   phase   air   Conditioners   are equipped   with   a   compressor   start   capacitor   and relay   and   a   compressor   run   capacitor. The  com- pressor  run  capacitor  (fig.  4-22),  is  located  in  the condenser   compartment   near   the   compressor.   The compressor   start   capacitor   and   relay   are   located under  the  center  top  cover  on  the  inner  wall  of  the junction   box   compartment   of   the   housing. b.  Removal.   Remove   the   capacitors   and   relay   as follows: (1)   Refer   to   paragraph   4-21   and   remove housing   covers. (2)   To   remove   run   capacitor,   disconnect   leads and   remove   two   screws   and   lock   washers   that secure   capacitor retaining   strap   (fig.   4-22)   to housing,   Remove   strap   and   capacitor. (3)  To  remove  start  capacitor,  refer  to  figure  4- 23,   disconnect   leads   and   remove   capacitor   from retainer. (4)  To  remove  start  relay,  refer  to  figure  4-23 and   disconnect   relay   leads.   Remove   screw   and   lock washer.   Remove   relay. install   capacitor with  two  screws c.   Installation.   Install   the   compressor   capacitors (3)   Refer   to   figure   4-22   and and   relays   as   follows: and   retaining   strap.   Secure   strap (1)  Refer  to  figure  4-23  and  install  relay  screw and   lock   washers.   Connect   leads. and   lock   washer.   Connect   leads. (4)   Refer   to   paragraph   4-21   and   install (2)  Refer  to  figure  4-23  and  install  capacitor  in housing   covers. retainer.   Connect   leads. 4-34

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business