Dehydrator.
M a n u f a c t u r e r
Alto Valve Co.
P a r t
n u m b e r
ADKOSZ
(modified
by
marking
07403
1321433557)
-Pyp~
S e a l e d - n o n - r e f i l l a b l e
(46) Actuator cylinder assembly.
Mannfacturer
Robert Shaw Controls Co.
P a r t n u m b e r
Poll-12 (modified by marking
0 7 4 0 3 13216E6128
a n d
changing
cable
attachment
plate)
Stroke
.052 in.
Full stroke pressure
( n o
l o a d )
240 rf: 20 psig
Pressure to start
s
t
r
o
k
e
165 rt 15 psig
(47) Dimensions and weights.
Length
27.8
in.
H e i g h t
20 in.
W i d t h
..........
30 in.
Weight
250
lbs.
1-7. Diagrams
a. Control System Schematic Diagrams.Refer to
figure l-4 and 1-5 for schematic wiring diagrams.
Figure 1-4. Control system schematic diagram, 1 phase, 50/60 hertz, 230 volts.
(Located in back of manual)
Figure l-5. Control system schematic diagram, 3phase, 50, 60 hertz and 400 hertz, 208 volts.
(Located in back of manual)
b. Wiring Diagrams.Refer to figures l-6 through
l-8 for wiring diagrams.
Figure 1-6. Wiring diagram, 1 phase,
50 / 60 hertz, 230 volts.
(Located in back of manual)
Figure l-7. Wiring diagram, 3 phase. SO/ 60 hertz, 208 volts.
(Located in back of manual)
Figure 1-8. Wiring diagram, 3 phase, 400 hertz, 208 volts,
(Located in back of manual)
1-9
|