TM 5-4120-243-24P
NOTE
b. Detailed assembly instructions for items
When a stock numbered item is requisi-
source coded to be assembled are found in TM 5-
tioned, the repair part received may
4120-243-14. Assembly components are listed im-
have a different part number than the
mediately following the item to be assembled.
part being replaced.
c. Repair parts kits and gasket sets listed at the
e. Federal Supply Code for Manufacturer
end of the repair parts listing for the last figure
(FSCM). The FSCM is a 5-digit numeric code listed
containing parts of the kit.
in SB 708-42 which is used to identify the manufac-
turer, distributor, or Government agency, etc.
d. The following publications pertain to the Air
Conditioner and its components.
f. Description. Indicates the Federal item name
and, if required, a minimum description to identify
TM 5-4120-243-14
Operator, Organizational,
the item. Items that are included in kits and sets
Direct and General Support
are listed below the name of the kit or set with the
Maintenance Manual for
quantity of each item in the kit or set indicated in
Air Conditioner, Horizon-
the quantity incorporated in unit column. When
tal Compact, 18,000 BTU.
the part to be used differs between serial numbers
Trane Models: 208V, 3-
of the same model, the effective serial numbers are
Phase j 50/60 Hertz, Model
shown as the last line of the description. In the
MAC6H18-208-1201-02;
Special Tools List, the initial basis of issue (BOI)
208V, 3-Phase, 400 Hertz,
appears as the last line in the entry for each special
Model MAC4H18-208-1201-
tool, TMDE, and support equipment. When densi-
03; 230V, l-Phase, 50/60
ty of equipments supported exceeds density
Hertz, Model MAC6H18-
spread indicated in the basis of issue, the total
280-1201-01; Harvey
authorization is increased accordingly.
W. Hottel Models: CH20-6-
08, 208V, 3-Phase, 50/60
H e r t z , CH20-4-08, 208
g. Unit of Measure (U/M). Indicates the stan-
Volts, 3-Phase 400 Hertz.
dard of the basic quantity of the listed items as us-
ed in performing the actual maintenance function.
This measure is expressed by a two-character
e. Identification of the usable on codes included
alphabetical abbreviation (e.g., ea, in., pr, etc.).
in column 3 of this publication are:
When the unit of measure differs from the unit of
issue, the lowest unit of issue that will satisfy the
Used On
Code
required units of measure will be requisitioned.
Model MAC4H18-208-1201-03, 208V,
BTP
h. Quantity Incorporated in Unit. Indicates the
3-phase, 400 hertz
quantity of the item used in the breakout shown on
Model F18H-4 (Keco), 208V, 3-phase,
CXM
the illustration figure, which is prepared for a
400 hertz
functional group, subfunctional group, or an
Model CH618-2, 208V, 3-phase, 50/60
CXR
assembly. A "V" appearing in this column in lieu
hertz
of a quantity indicates that no specific quantity is
Model CH20-6-08, 208V, 3-phase
BXD
applicable (e.g., shims, spacers, etc.).
60/60 hertz
BWX
Model CH20-4-08, 208V, 3-phase, 400
hertz
4. Special Information.
a. Detailed manufacturing instructions for item
source coded to be manufactured or fabricated are
found in TM 5-4120-243-14. Bulk materials re-
quired to manufacture items are listed in the Bulk
Material Group of this manual.
4
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |