TM 5-4120-259-15
b. Removal. Remove the condenser fan mo-
tor as Shown by figure 17.
c. Disassembly.
(1)
(2)
(3)
(4)
(5)
Remove nuts and
through-bolts
which secure end shields to stator
frame. Remove right end pkke from
the stator frame.
Note. Mark the end platas and stator
frame prior to disassembly to facilitate
matching of mating parts during reassem-
bly.
Remove rotor assembly with left end
plate attached.
Remove the left end plate.
Remove the washers, bearings and
slingers from the shaft of the rotor
assembly.
Tag and disconnect the leads of the
stator assembly from the motor con-
nector and thermal protector and re-
place these items if necessary.
(6) Replace stator assembly if necessary.
d. Cleaning, Inspection and Repair.
(1)
(2)
(3)
(4)
Clean all metal parts with an ap-
proved cleaning solvent and dry
thoroughly with compressed air and
a clean cloth.
Rotate bearings and inspeot for any
wear.
Inspect the rotor assembly for a bent
shaft, Replace a defective rotor.
Inspect all other parts for defects or
damage. Replace all unservicable
parts.
e. Testing. Test the stator assembly for
short circuits as instructed in TM 5-764.
f. Reassembly. Reassemble motor in reverse
order of disassembly.
g. Installation. Install motor as shown by
figure 17.
5
8
|