(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
SMR
DESCRIPTION
UNIT QTY 30 DAY DS MAINT 30 DAY GS MAINT
1-YR
DEPOT
ILLUS-
CODE
OF
INC
ALLOWANCE
ALLOWANCE
ALW PER MAINT
TRATION
FEDERAL
USABLE
MEAS IN
100
ALW PER (a) (b)
STOCK
ON
UNIT (a)
(b)
(c)
(a)
(b)
(c)
EQUIP
100
FIG. ITEM
1-20 21-50 51-100 1-20 21-50 51-100 CNTGY
EQUIP
NUMBER
REF. NUMBER & MFR CODE
CODE
NO. NO.
CONNECTOR, RECEPTACLE,
ELECTRIC: J12 HARNESS,
AS REQUIRED, P/N NS31OOR28-95Z (96906)
WIRE, ELECTRICAL, 16 AWG
AS REQUIRED, FSN 6145-578-7517
WIRE, ELECTRICAL, 14 AWG
AS REQUIRED, FSN 6145-578-7516
MO
WIRING HARNESS: P5, P1O, P11 AND P16
EA
1
FROM JUNCTION BOX TO COMPRESSOR,
PRESSURE SWITCH AND SOLENOID VALVE
B4525-612 (60532)
MANUFACTURE FROM:
CONNECTOR, PLUG, ELECTRIC:
P5 HARNESS. 1 REQUIRED,
FSN 5935-725-4638
CONNECTOR, PLUG, ELECTRIC:
P16 HARNESS, 1 REQUIRED,
P/N S3106R12535Y (96906)
CONNECTOR, PLUG, ELECTRIC:
P11 HARNESS 1 REQUIRED,
FSN 5935-878-7588
CONNECTOR, PLUG, ELECTRIC:
P10 HARNESS 1 REQUIRED
P/N MS310R36-1IPX (96906)
WIRE, ELECTRICAL, NO. 16 AG,
AS REQUIRED, FSN 6145-578-7517
WIRE, ELECTRICAL, NO. 10 AWG
AS REQUIRED, FSN 6115-578-7513
MO
WIRING HARNESS: P6, P12 AND J7
EA
1
FROM J12 TO SOLENOID VALVE AND P7
B4525-614 (60532)
MANUFACTURE FROM:
CONNECTOR, PLUG, ELECTRIC:
P6 HARNESS, 1 REQUIRED,
FSN 5935-725-638
CONNECTOR, PLUG, ELECTRIC:
P12 HARNESS, 1 REQUIRED
P/N MS3106R28-9PZ (96906)
CONNECTOR, RECEPTACLE, ELECTRIC:
J7 HARNESS, 1 REQUIRED,
P/N MS31OO8-9SX (96906)
WIRE, ELECTRICAL, NO. 16 AWG,
AS REQUIRED, FSN 6145-578-7517
WIRE, ELECTRICAL, NO. 14 AWG
AS REQUIRED, FSN 615-578-7516
MO
WIRING HARNESS: J1 AND P13,
EA
1
POWER INPUT
B4525-615 (60532)
MANUFACTURE FROM:
CONNECTOR, PLUG, ELECTRIC: P13,
1 REQUIRED, P/N MS316R24-22SX (96906)
CONNECTOR, RECEPTACLE, ELECTRIC:
J1, 1 REQUIRED,
P/N MS31ODR24-22P (96906)
WIRE, ELECTRICAL, NO. 8 AWG,
AS REQUIRED, FSN 6145-578-7515
26
|