TM 5-4120-270-15 Section IV.  OPERATOR’S 3-8. General The   instructions   in   this   section   are   published   for   the information and guidance of the operator to maintain the air  conditioner.  learning:  Disconnect  the  air  conditioner from the power source before performing any maintenance on the components of this unit. 3-9. Air Filter Service a. General.    The  air  filters  are  located  under  the evaporator blower assembly. They remove airborne particles of dust and other contaminants from the conditioned area. b. Removal.    Refer  to  figure  34  and  remove  filter access doors and filters. c. Servicing.  Refer to figure 34 and service both air filters. d. Installation.  Refer to figure 3-3 and install filters and access doors in reverse order of removal. 3-10. Mist Eliminator and Evaporator Coil Service a. General.    The  mist  eliminator,  located  between the  air  discharge  grille  and  the  evaporator  coil, removes  moisture  from  the  air  after  the  air  has passed over the evaporator coil. The    evaporator coil    is    to    be    cleaned    each    time    the    mist eliminator is serviced.  The coil may be cleaned without removal from air conditioner. b. Maintenance  Procedure.    Refer  to  paragraph  8- 25   and   remove   the   evaporator   air   discharge grille  and  top  cover  panel.    Refer  to  figure  8-4 and perform prescribed maintenance service. c. Installation.    Refer  to  figure  34  and  install  the mist eliminator.   Install evaporator discharge grille and top cover panel (para S25). 3-11. Condenser Coil a. General.    The  condenser  coil  may  be  cleaned without removal from the air conditioner. b. Maintenance Procedure.  Refer to figure 3-5 and perform prescribed maintenance service. 3-4

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business