Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: Tabulated Data
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 5-4120-270-15 e.    Evaporator Fan Motor Classification and Rating. Type........................................    Induction, squirrel cage .......................................... rotor, double extended shaft Duty ........................................   Continuous Drive .......................................   Direct Protection................................   Automatic reset internal .......................................... thermal overload and .......................................... overcurrent MAC4V6--604 MAC6V6O-360-2 Rating ......... 1.60 HP    .............1.25 HP Voltage ...................... 208V AC............   208V AC Phase .................... 3    ........................3 Frequency ...................... 400 cycles .........   60 cycles Speed ....... 3600 rpm    ...........3450 rpm f. Electric Heaters Classification an d Rating. Type........................................   Folded, stainless  steel- ................................................   sheathed tubular elements. Rating (at 120 volts)................   2100 watts each Duty ........................................   Continuos Protection................................   Automatic reset external ................................................   overload and overcurrent. g. Temperature   Control   Thermostat   Classification   and Rating. Type........................................   Single pole, double-throw, .........................................   normally closed bimetallic .........................................   element. Range .....................................   +40*F to +90°F Closing differential ..................  21F h.Selector Switch Classification and Rating. Type........................................   Rotary, five positive ......................................... dent positions. Rating .....................................  15 amperes at 208V AC i.Heater    High    Temperature    Cutout    Classification    and Rating. Type........................................   -Automatic reset thermal .........................................  overload and overcurrent, .........................................  normally closed. Range .....................................  Closed 140° t 9°F; open .........................................  1900 * 9°F Rating .....................................  180 amperes at 208V AC j.Magnetic Contactor Classification and Rating. Type........................................  Three-pole, single-throw, .........................................  normally open, class AS. Duty ........................................   Continuous Control coil..............................  28V DC Rating: (1) ....................................  0 amperes at 208V AC .........................................  (2 per unit) (2) ....................................   26 amperes at 208V AC .........................................  (3 per unit) k.Time Delay Relay Classification and Rating. Type........................................   Single-pole, single-throw, .........................................  normally open, thermal .........................................  delay, hermetically sealed. Delay.......................................  30 seconds Rating .....................................  8 amperes at 28V DC l.Circuit Breaker Classification and Rating. Type........................................  Manual reset double-pole, .........................................  double-throw with single- .........................................  pole, single-throw auxiliary. Trip time, main breaker: Locked rotor ....................   1.5 6.0 second Rated overload ................   30 minutes maximum Rating, main MA Cs V60460 MAC6V-460.  4 breaker Must hold ..........   49.0 ampere 44.2 amperes Must trip ............   61.2 amperes ........50.8 ampere Rating, auxiliary.2.5 amperes at 250V_AC m.  Transformer Classification and Rating. Type........................................    Stepdown, single phase Input voltage ...........................   208V AC Output voltage ........................   30V AC Output current ........................   2.2 amperes continuos; 7.7 amperes surge. n.  Rectifier Classification and Rating. Type........................................    Silicon rectifier full-wave ............................................... bridge, stud mount am Input voltage ...........................   SOV AC Output voltage ........................   24V AC Output current ........................    3.0 ampere  maximum o.  RFI Filter Classification and Rating. Type........................................   Feed through Rating .....................................   .5 amperes at 2SOV AC p.  Expansion Valve Classification and Rating Type........................................    Compensated thermal expansion ...............................................   remote bulb Superheat-----------_--_.100 + 1/2"F Rating .....................................   4 1/2 ton (1 par unit) and ............................................... 2.1 ton (1 per unit) q.  High Pressure Cutout Classification and Rating. Type........................................   Manual reset normally ........................................   closed pressure operated ........................................   single-pole, single-throw. Trip pressure ..........................   445 F 10 pig (pounds per ........................................   square inch gag.). Reset pressure .......................   400 psig r.  Low Pressure Classification and Rating. Type........................................    Manual reset, normally ........................................   closed pressure operated ........................................   single-pole, single-throw. Trip pressure ..........................   7 5 psig Reset pressure .......................   12 5 psig s.  Solenoid Valve Classification and Rating. Type........................................   Normally open, pilot oper ........................................   ated with integral  at ........................................   and resilient disc Coil voltage: Pull-in ..............................   20.4V DC Release ...........................   18.0V DC Coil current .............................   0.51 amperes (holding). t.      Back   Pressure   Regulating   Valve   Classification   and Rating. Type........................................   Pressure operated, normally ........................................ closed Operating range-__ --------90 psig Opening pressure ...................    psig preset, adjustable u.  Pressure Relief Valve Clarification and Rating. Type........................................   Spring loaded, normally ........................................   closed, non-adjustable Release pressure ...................   40 pig. 4-2

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business