TM 5-4120-287-15
3-41. Remote Control Box Wiring Harness
a. Removal.
(1) Make sure input power plug P101 is disconnected from electrical tray panel input power receptacle J101.
(2) Disconnect remote control box harness from the remote control box and from the electrical tray panel remote,
control receptacle.
b.
Inspection and Testing
(1) Inspect remote control box harness assembly for physical defects in accordance with paragraph 3-38b. Replace
a defective harness assembly.
(2) Test for electrical defects as follows:
(a) Using a multimeter or test lamp, test for continuity of individual harness wires by placing one test lead on
harness plug P102, prong a; and the other test lead on plug P103, prong A. Continue testing P102 and P103 positions
B, C, D, E, F, G, H, J, K, and L, in this manner. Make sure that the test leads are on plug P102s and P103s associated
prongs (A-A, B-B, C-C thru L-L) while observing for multimeter needle deflection or test lamp glow. Replace the remote
control harness assembly should the multimeter or test lamp indicate discontinuity in one or more of the above tests.
c.
Installation.
(1) Connect the harness to the remote control box and electrical tray panel remote control receptacle.
(2) Connect input power plug P101 to electrical tray panel input power receptacle J101.
3-20
|