ME    4120-308-15/3-9 Figure   3-9.   Fresh   air   damper   door   control   chain. mum  INCREASE  position,  check  for  continuity between  terminals  1  and  2.  Continuity  should  be indicated.   If   no   continuity   is   indicated,   thermo- stat is defective and must be replaced. c. Removal. ( 1 ) Refer  to  paragraph  3-26  and  remove  the control panel. (2)   Refer   to   figure   3-11   and   remove   the thermostat. d. lnstallation.   Installation  is  the  reverse  of  re- moval. 3-29.   Two-speed Condenser Fan Selector Switch. a.  General.  The   two-speed   switch   provides   the user  the  option  of  selecting  either  HI-SPEED  or LO-SPEED   air   circulation.   When   the   switch   is placed  in  the  HI-SPEED  position,  the  fan  speed will  remain  constant  until  the  unit  is  either  shut down  or  the  switch  is  placed  in  the  LO-SPEED position.  When  the  air  conditioner  is  operated with  the  fan  switch  in  the  LO-SPEED  position, an   increase   in   compressor   discharge   pressure   to 400   (±16)   psig   will   actuate   the   normally   open pressure  switch  (S3),  causing  the  switch  to  close and   the   fan   speed   to   increase   to   HI-SPEED. When  the  discharge  pressure  drops  to  350  (±16) psig,  the  pressure   switch   (S3)   contacts   will   re- 3-14 turn  to  normally  open  and  the  fan  speed  will  re-           turn  to  LO-SPEED. b.   Testing. (1)  With   power   off   and   switch   in   HI- SPEED   position,   remove   wire   No.   V3C16   from (fig.  1–40)  and  check  continuity  between  it  and X2  of  K5.  Continuity  should  be  indicated.  If  con- tinuity   is   not   indicated,   switch   is   defective   and must be replaced. (2)   With   power   off   and   switch   in   LO- SPEED   position,   remove  wire  No.  V3C16  from XF2  (fig.  1-4  0)  and  check  for  no  continuity  be- tween  it  and  X2  of  K5.  Continuity  should  not  be indicated.  If  continuity  is  indicated,  switch  is  de- fective and must be replaced. c. Removal. (1)  Refer  to  paragraph  3-26  and  remove  the control panel. (2)  Refer  to  figure  3-11 switch. d.  lnstallation.   Installation moval. 3-30. Junction Box and  remove  the  fan is  the  reverse  of  re- a.  General.  The  junction  box  is  located  at  the bottom  front  of  the  air  conditioner.  Access  is gained  by  removing  the  f  rent  access  cover.  The junction  box  houses  the  phase  sequence  relay,  ar-

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business