Page Title: Figure 6-4. Pressure testing and evacuating there refrigerant system.
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

WARNING: Figure  6-4.  Pressure  testing  and  evacuating  there  refrigerant  system. d.  Charging.   Refer   to   figure   6-5   and   6-6   and system   operating   pressure   test.   This   test   should charge  the  refrigerant  system. be   performed   under   controlled   conditions   at   the ambient  temperatures  specified  in  table  5-2.  The 6-6. System Operating Pressure Test system   operating   pressure   test   is   performed   as follows : An   important   part   of   diagnosing   the   air   condi- tioner  refrigerant  system  troubles  to  effect  prop- a.  Refer  to  figure  6-4  and  remove  the  suction cr   repair   procedures   is   the   performance   of   a and discharge service valve caps. 6 - 6