Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: CHAPTER 4 DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE INSTRUCTIONS
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

CHAPTER  4 DIRECT   SUPPORT   AND   GENERAL   SUPPORT MAINTENANCE   INSTRUCTIONS Section   I.   REPAIR   PARTS,   SPECIAL   TOOLS AND   EQUIPMENT 4-1.   Tools   and   Equipment. direct   or   general   support   maintenance   personnel   to Tools   and   equipment   issued   with   or   authorized   for maintain   the   air   conditioner. the  air  conditioner  are  listed  in  the  basic  items  list, 4-3.   Maintenance   Repair   Parts. appendix   C. Direct   and   general   support   maintenance   repair 4-2.   Special   Tools   and   Equipment. parts are listed in T M     5 - 4 1 2 0 - 3 3 5 - 2 4 P. There  are  no  special  tools  or  equipment  required  by Section   II.   TROUBLESHOOTING 4-4.    General. The   corrective   action   recommended   is   described This   section   provides   information   useful   in opposite  the  probable  cause.  The   troubleshooting diagnosing  and  correcting  unsatisfactory  operation operations  shown  in  table  4-1  are  only  those  which or   failure   of   the   air   conditioner   or   any   of   its cannot   be   performed   at   organizational   maintenance components.   Malfunctions   which   may   occur   are levels   (see   table   3-2   for   organizational   maintenance listed   in   table   4-1,   Each   malfunction   stated   is troubleshooting).  Refer  to  FO-3  (Located  in  the followed  by  a  list  of  probable  causes  of  the  trouble. back   of   manual)   for   refrigeration   schematic. Table   4-1.   Troubleshooting Malfunction 1. Compressor will not start. 2.   Cooling   insufficient   in   cooling position. 3.   Cooling   excessive   in   cooling position. 4.  Heater  does  not  heat  properly. Probable  Cause a. Corn   presser   defective. b.  P o w e r    s w i t c h ,    s w i t c h    N o ,   2 defective, c.   Selector   switch,   switch   No.   2 defective. d.  Thermostatic   switch   defective. e.  Power   relay   defective. f.  Starting    capacitor    defective. a.  Evaporator   fan   motor   defective. b.  Condenser   fan   motor   defective. c.  Compressor     defective. d.  Thermostatic   switch   defective. ?.   Filter   drier   clogged. a.  Thermostatic    expansion    valve defective. b.  Power   relay   defective. c.   Thermostatic   switch   defective. a. Heater   overtemperature   protector, thermostat    defective. b.  Selectro   switch,   switch   No.   3 defective. c.   Thermostatic   switch   defective. Corrective  Action a.  Replace   compressor,   (para   4-14). b.  Replace    switch,    (para    3-25). c.   Replace   switch,   (para   3-25). d.  Replace   switch,   (para   4-18). e.  Replace   relay,   (para   3-27). f.  Replace   capacitor,   (para   3-20). a.   Replace   motor,   (para   3-17). b.  Replace   motor,   (para   3-18). c.  Replace   compressor,   (para   4-14). d.  Replace   switch,   (para   4-18). e.  Replace   filter   drier,   (para   4-12). a.  Replace   valve,   (para   4-17). b.  Replace   relay,   (para   3-27). c.   Replace   switch,   (para   4-18). a.  Replace    heater    over-temperature protector,   thermostat,   (para   3- 24). b.  Replace   switch   No.   3,   para   3-25). c.   Replace   switch,   (para   4-18). 4-1

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business