Click here to make tpub.com your Home Page

Page Title: Identification and Tabulated Data
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Capacity  .  .  .  .  .  .  9,000  BTU/HR
military model number, federal stock number,
S t o c k Number . . . . . FSN 4120-831-8238
aerial number, specification number, part number,
Manufacturer . . . . . . . Harvey W. Hottel, Inc.
contract number, date, weight and capacity.
(2) C o m p r e s s o r i d e n t i f i c a t i o n p l a t e . L o c a t e d
(2) E v a p o r a t o r a n d c o n d e n s e r f a n m o t o r .
on the front of compressor housing. Specifies
Manufacturer . . . . . . . . Welco Industries
compressor model number, part number, serial
Part Number . . . . . . . . . . . . . 4715-18
Hp (Horsepower) . . . . . . . . . . .86/.10
number,  refrigerant, oil type  and  capacity,
Type . . . . . . . . . . . . . . . . . . . . Double extended shaft
manufacturer and complete electrical data.
Volts . . . . . . . . . . . . . . . . . . 115
(3) F a n m o t o r i d e n t i f i c a t i o n . L o c a t e d o n t o p
Amp (amperes) . . . . . . . . . . 8.0/1.40
o f the fan motor. Specifies motor horsepower, serial
Frequency . . . . . . . . . . . . . . . .60 Hertz
num her, rpm  ( r e v o l u t i o n s p e r m i n u t e ) , a n d
Phase . . . . . . . . . . . . . . . . . . . .1
e l e c t r i c a l  characteristics.
RPM . . . . . . . . . . . . . . . .3450/1750
Duty . . . . . . . . . . . . . . . . . . . . . Continuous
(4) Control panel legend plate. L o c a t e d  o n
Drive . . . . . . . . . . . . . . . . . . . Direct
the front of the unit control panel. Indicates unit
t e r m p e r a t u r e setting for cooling or heating purposes,
(3) P e r f o r m a n c e  D a t a .
mode selector switch and fan speed switch.
Cooling Capacity . . . . . . . . . .9,000 BTU/HR nominal
(5) W i r i n g d i a g r a m p l a t e . L o c a t e d o n i n s i d e
9,500  BTU/HR  actual  at
1 2 0 F DB, Air to Con-
of front access panel, illustrates complete unit
d e n s e r , 90 F DB, 75 F
wiring.
WB, return air to unit.
(6) R e f r i g e r a n t 2 2 p l a t e . L o c a t e d o n t h e r e a r
Capacity
6,000
BTU/HR
(hi-beat
and
panel in upper left area. It states that the unit is
h i - s p e e d positions) 3,000
charged with 3.31 pounds of refrigerant 22.
BTU/HR  (lo-heat  and  hi-
speed positions)
(7) Color indicating plate. Located on the
rear panel immediately above the liquid line sight
(4) D i m e n s i o n s a n d w e i g h t .
glass. It has three color bands: green, chartreuse,
Length . . . . . . . . . . . . . . . . . 17 in.
a n d yellow which are used in conjunction with the
Width . . . . . . . . . . . . . . . . . . . 17 in.
l i q u i d sight line glass to indicate moisture condition
Height . . . . . . . . . . . . . . . . . .32 1/8 in.
Weight . . . . . . . . . . . . . . . . . 170 lbs.
of the refrigerant.
(8) High and low pressure cutout control reset
(5) E v a p o r a t o r a n d c o n d e n s e r f a n s .
plate. Located on rear panel at the high and low
Manufacturer . . . . . . . Harvey W. Hottel, Inc.
pressure  cutout  control  reset  buttons  with
Type
.
.
.
.
.
.
Condenser-propeller,
nomenclature: " P U S H T O R E S E T " .
Evaporator-centrifugal
(9) Indicating arrow plate, L o c a t e d o n t h e
Number per unit . . . . . . . .1 each
Rotation (facing condenser
rear panel just above the condenser fan guard; the
air discharge grille) . . Clockwise
a r r o w indicates direction of condenser fan rotation.
(10) C o m p r e s s o r  circuit  breaker  reset
(6) C o m p r e s s o r r e l a y .
plate. Located on the lower right side of the air
Manufacturer . . . . . . . . . . . . Cutler-Hammer
conditioner.  It  states:  " C I R C U I T  B R E A K E R
Part Number . . . . . . . . . . . . .MS24192-D1
AMP. . . . . . . . . . . . . . . . . . . . .25
RESET".
Type . . . . . . . . . . . . . . . . . . . . Three pole, single throw
(11) Refrigerant piping plate. Located  on
norm ally open
outside of front access panel.
Coil voltage . . . . . . . . . . . . ..28 VDC
(12) Service gage plates, Located beside the
(7) Temperature
control
thermostat.
access cover on the rear panel. They state:
Manufacturer
Penn
Controls
"SUCTION
SERVICE
VALVE"
and
A19AGF-10
Part Number . . . . . . . . .
"DISCHARGE  SERVICE  VALVE",
Action . . . . . . . . . . . . . . . . . . . Single pole, double throw
(13) C o m p r e s s o r  circuit  breaker  reset
Range . . . . . . . . . . . ..+40 F to 90F
p l a t e . Located on the back of the unit on the CBR
Differential . . . . . . . . . . . . . . 2 F
duct cover. It states:  " P U L L  A N D  P U S H  T O
Electrical rating . . . . . . . 5.8 Amps at 120 VAC
RESET  CIRCUIT  BREAKER".
(8) Mode selector switch.
(14) Damper operation plate. Located  on
Manufacturer
Cutler-Hammer
return air grille on front of air conditioner. It
Type . . . . . . . . . . . . . . . . . . Rotary (Manual)
states: "FRESH  AIR  DAMPER  CHAIN  PULL
Part Number . . . . . . . . . . . . . 8912K216
TO CLOSE".
Number of positions . . . . . . 5 (hi-heat, lo-heat. off, ven-
b. Tabulated Data.
tilate, cool)
Electrical rating . . . . . . . . 15 amp. 250 VAC
(1) A i r  c o n d i t i o n e r  i d e n t i f i c a t i o n  p l a t e .
Air conditioner . . . . . Vertical. compact, Harvey W.
(9) F a n s p e e d s w i t c h .
Hottel Model CV-9-5/6-15,
Type . . . . . . . . . . . . . . . . . . .. Single pole
Specification
MIL-A-
Part Number . . . . . . . . . MS24523-22
32513A(ME), Class 1, 115
Position . . . . . . . . . . . UP-Hi speed, DOWN-lo speed
Volts  A.C.,  60  Hertz,  1
Electrical rating . . . . . . . . . . 15 Amps at 28 VDC
phase.
1-5

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business