Click here to make tpub.com your Home Page

Page Title: Heating
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM5-4120-347-14
The low pressure switch (2), the high pressure switch (14) and the pressure relief valve (13) are
provided to protect the unit from damage due to pressure extremes.
a. When the MODE SELECTOR is set for HIGH heat, all heating elements, located behind the evaporator
coil are energized. These elements are protected from overheating by a thermal cutout switch. Half of the
elements are thermostatically controlled by the TEMPERATURE SELECTOR, and remaining half are on all of
the time. When set for LOW, only the thermostatically controlled elements are energized.
b. The two speed fan can be set for either HIGH or LOW operation during heating
1-9/(1-10 blank)

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business