open damper door and p a r t i a l l y c l o s e i n t a k e d a m p e r .
( f )  F o r cooling with a mixture of recirculated air and fresh air
drawn through a chemical biological, radiological filter unit when outdoor air is
c o n t a m i n a t e d , close damper door and partially close intake grille damper. (Applic-
able only if the unit is equipped with a chemical biological radiological (CBR)
filter  unit.
(2) Heating Operation.
( R e f e r to figure 2-1 and 2-2.)
(a)
Position thermostat for desired temperature.
Place fan speed toggle switch in desired position.
(b)
P l a c e selector switch on `LO-HEAT" or "HI-HEAT" position.
(c)
( d )  F o r heating with 100 percent recirculated air, close damper
d o o r and open intake g r i l l e d a m p e r .
( e )  F o r heating with a mixture of recirculated air and fresh air,
open damper door and p a r t i a l l y c l o s e i n t a k e g r i l l e d a m p e r .
( f )  F o r heating with a mixture of recirculated air and fresh air
d r a w n through a chemical, biological., radiological filter unit when outdoor air is
c o n t a m i n a t e d , close damper door-and partially-close intake grille damper. (Applic-
a b l e only if the unit is equipped with a chemical, biological, radiological (CBR)
filter  unit.
(3)
V e n t i l a t i n g Operation.
( R e f e r to figures 2-1 and 2-2.)
( a ) Place selector switch in "VENTILATE  f' position.
(b) Place fan speed toggle switch in desired position.
( c ) Open damper door and close intake grille damper.
NOTE
If the air conditioner fails
t o start, pull, then push
t h e circuit breaker knob.
S t o p p i n g . T u r n the selector switch to "OFF". (Refer to figure 2-1.)
c.
Section IV. Operation Under Unusual Conditions
OPERATION IN EXTREME COLD
2-5.
a .  T h e air conditioner is designed to o p e r a t e o n t h e c o o l i n g c y c l e w i t h o u t
f o r m i n g f r o s t o r i c e o n t h e e v a p o r a t o r c o i l a t a n ambient (outside) temperature as
l o w as 50F (10C).
If cooling air is desired at ambient (outside) temperatures lower than
b.
2-5