4120-01-069-1321)">
|
|
![]() TM 5-4120-359-14
Figure 4-66. Motor (B2) Welco Industries, Inc.
(d) Tag and unsolder leads.
(e) Remove the old connector.
(f) See wiring diagram and tags and solder leads to the new connector. Remove the tags.
(g) Using screwdriver, install the connector with four screws.
(h) Using screwdriver, install the terminals box cover with four screws.
(2) To replace bearings on IMC Magnetics Corporation motors:
(a) Using screwdriver, remove four screws from each end bracket and carefully remove the end caps.
(b) Note the position and number of springs, shims, and bearings as they are removed.
(c) Remove the bearing shim(s) and load spring.
(d) Remove the bearings.
(e) Place the new bearings on the shafts.
(f) Place the spring and shim(s) back of shaft in same position as removed.
4-136
|