TM 5-4120-364-13
(c) Tag
and
disconnect
eletrical
leads
from
selector
switch
(18)
and
remove jumper (19).
then remove selector switch (18).
( d ) Remove screws (13), washers (3),
( 2 ) Inspection.
( a ) Check selector switch for freedom of retation by rotating the kncb
3 6 0 degrees.
( b ) Check continuity through selector switch with a circuit tester,
If selector switch is found to be defective, it must be replaced. Refer to Table 3-3.
TABLE 3-3.
SWITCH FUNCTIONS
SWITCH
SWITCH
POSITION
FUNCTION
WAFER 1
WAFER 2
WAFER 3
1
OFF
4 AND 5
2
VENT
4 5 AND 6
3
COOL
5 AND 6
7 AND 8
EXT CONTROL
4
4 AND 6
9 AND 10
(3) Installation,
( a ) Position selector switch (18) on back of control panel (16) and
secure with screw (13) and washers (3).
(b) Connect electrical leads and jumper to selector switch terminals.
(c) position control panel (16) in position and secure with fasteners
(22) by turning fasteners one-quarter turn clockwise.
( d ) Place control knob on selector switch shaft and secure with set-
screw.
d. Temperature Control. Access to the temperature control is gained by re-
m o v i n g knob (24, figure 3-10) f r o m shaft of temperature control (27) and turning
fasteners (22) one-quarter turn counterclockwise and removing control panel (16).
(1) Removal.
(a) Tag and disconnect electrical leads from temperature control (27).
( b ) Loosen screws holding thermostat bulb t o the evaporator coil frame
b r a c k e t and slide bulb out. Push t u b i n g and bulb through bulkhead.