4-22. JUNCTION BOX AND CONTROL MODULE ASSEMBLY/Inspect, Test, Replace (Cont)
LOCATION/ITEM
Test:
8. Using a multimeter check for continuity between terminals 2 and 3.
9. If continuity does not exist the temperature selector is defective.
10. Replace defective temperature selector (S-3).
Connector With Leads
1. Using a multimeter test for continuity between connector pins and terminations in
accordance with wiring diagram Appendix E.
2. If continuity does
3. Repair or replace
not exist connector with leads defective.
defective connector with leads.
Installation:
Connector With Leads
1. Align connector module mounting post (59) with holes in connector (56).
2. Secure connector module mounting post and connector J-2 with two screws (57) and two
lock nuts (58).
3. Align connector with holes in control module mounting frame.
4. Secure above
5. Attach wires
6. Align control
(40).
with eight screws (53) eight lock washers (55) and eight nuts (54).
to appropriate terminals.
mounting plate (38) and control module designation plate (39) with four posts
4-102
|