TM5-4120-376-14
4-22. JUNCTION BOX AND CONTROL MODULE ASSEMBLY/Inspect, Test, Replace (Cont)
LOCATION/ITEM
Installation:
5.
(76).
7.
Align wiring harness ground with hole in junction box.
Secure ground with one screw (73) one flat washer (74) one lock washer (75) and one nut
Attach wires to appropriate terminals in accordance with Appendix E and remove tags.
Connector With Leads J-1
1. Align wiring harness connector (71) and gasket (72) with holes in junction box.
2. Secure wiring harness to junction box with four screws (66) four flat washers (67)
identification tag (68) connector cover and four lock nuts (70).
3. Attach wires to appropriate terminals in accordance with Appendix E and remove tags.
Relay K8
1.
2.
3.
Align relay K8 (65) with holes in junction box.
Secure relay K8 to junction box with four screws (63) and four lock nuts (64).
Attach wires to appropriate terminals in accordance with Appendix E and remove tags.
Relay K1
1. Align relay K1 (62) with holes in junction box.
2. Secure relay K1 to junction box with four screws (60) and four flat washers (61).
3. Attach wires to appropriate terminals in accordance with Appendix E and remove tags.
Relay (K5)
Attach wires to appropriate terminals in accordance with Appendix E and remove tags.
4-115
6.
|