TM  5-4120-377-14 RETURN  AIR  FILTER  -  Provides  filtered  return  air. INTAKE  (RETURN)  AIR  GRILLE  -  Adjustable  louvers  allow  control  of  outside  (fresh)  and  return (from  room  or  enclosure)  air. CONTROL   PANEL   -   Contains thermostat. The  control  panel  is  shown  in  its a  five  position  mode  selector  switch  and  a  temperature  control NOTE location  when  the  air  conditioner  is  installed  as  a  self- contained unit. The control panel is designed so that it may be removed from the cabinet and  installed  in  a  remote  location.  See  installation  instructions  (para  4-7). JUNCTION  BOX  -  Contains  and  protects  electrical  system  control  devices. EVAPORATOR  COIL  -  Serves  as  a  heat  exchanger  by  transferring  heat  from  the  air  passing  over the  tubing  and  fins  to  the  refrigerant  passing  through  the  tubing. FABRIC  COVER  -  Shown  on  rear  view  in  stowed  (operational)  position.  When  rolled  down  and snapped  it  protects  the  rear  (exposed)  surface  of  the  unit. FRESH  AIR  FILTER  AND  DAMPER  -  Provides  filtered  outside  air. REFRIGERANT   SIGHT   GLASS   (liquid   sight   indicator)   -   Allows   visual   inspection   and   indicates condition  of  liquid  refrigerant  when  the  unit  is  operating  in  the  cool  mode. INPUT  POWER  RECEPTACLE  -  For  connection  of  external  power  source  cable. NOTE The  air  conditioner  is  designed  so  that  the  input  power  receptacle  may  be  used  in  the front  panel  location  shown,  or  it  may  be  moved  to  one  of  four  other  alternative  locations. See  installation  instructions  (para  4-9). HIGH   AND   LOW   REFRIGERANT   PRESSURE   CUTOUT   SWITCHES   (S6   and   S7)   -   Protects compressor  from  possible  damage  due  to  excessively  high  or  low  refrigerant  pressures. COMPRESSOR   CIRCUIT   BREAKER   (CB1)   RESET   KNOB   -   Actuates   a   push-pull   type   control cable  for  resetting  compressor  circuit  breaker. CONDENSER  AIR  OUTLET  GRILLE  -  Protects  personnel  from  injury  and  fan  from  damage. COMPRESSOR  (B1)  -  Pumps  refrigerant  through  the  system  during  cooling  operations. CONDENSER   COIL   -   Serves   as   a   heat   exchanger   by   transferring   heat   from   the   refrigerant passing  through  the  tubing  to  the  air  passing  over  the  tubing  and  fins. CONDENSER  COIL  GUARD  -  Protects  coil  from  damage. CONDENSATE  WATER  DRIP  PAN  AND  DRAIN  TRAP  -  The  drip  pan  is  located  directly  below the   evaporator   coil   and   mist   eliminator   and   is   built   into   the   casing.   Its   purpose   is   to   collect condensate   that   drips   off   the   evaporator   coil   and   mist   eliminator   during   cooling   operations. Condensate water then flows through tubing to the drain traps located inside the lower right and left hand  front  corners  of  the  cabinet.  The  drain  traps  contain  check  valves  that  prevent   air  flow between  the  condenser  and  evaporator  sections  through  the  drain  tubing. 1-4

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business