TM  5-4120-377-14 l The  expansion  valve  (8)  controls  the  amount  of  pressure  of  liquid  refrigerant  to  the  distributor  (9)  and evaporator  coil  (10).  The  expansion  valve  (8)  senses  the  temperature  and  pressure  of  the  refrigerant  as  it leaves  the  evaporator  coil.  By  use  of  a  sensing  bulb  and  “external  equalizer  line”  the  valve  constantly  adjusts the  flow  of  liquid  refrigerant  to  the  evaporator  coil  (10). l As  the  Iiquid  refrigerant  leaves  the  expansion  valve  (8)  it  passes  thru  a  distributor  (9)  and  enters  the evaporator  coil  (10).  As  the  liquid  enters  the  coil  at  a  reduced  pressure,  the  reduction  in  pressure  and  the warmer air being forced across the tubes of the coil cause the refrigerant to boil and change to a gas (vapor). The  evaporator  fan  circulates  the  warm  air  from  the  conditioned  space  over  and  through  the  evaporator  coil. Refrigerant absorbs heat when it changes from a liquid to a gas. As the air from the conditioned spaces comes in  contact  with  the  evaporator  coil  (10),  the  air  is  cooled. l The  refrigerant  gas  is  then  drawn  back  to  the  compressor  (1)  and  the  cycle  is  repeated. b.  Bypass  cycle.  This  unit  has  a  bypass  cycle  which  allows  cooling  operation  at  low  cooling  loads  without cycling the compressor (1) on and off. In bypass, the refrigerant is piped from the discharge (high side) to the suction  (low  side)  of  the  compressor,  bypassing  the  evaporator  coil  (10). l When   the   temperature   control   thermostat   on   the   control   panel   senses   that   cooling   conditions   have reached the set point, it closes the liquid line solenoid valve (6) to shut off refrigerant flow to the evaporator coil (10). l As the compressor suction pressure starts to drop, the pressure regulating valve (12) opens to allow flow of  hot  gas  from  the  compressor. l The   expansion   valve   (quench)   (11)   senses   the   temperature   of   the   gas   at   the   suction   side   of   the compressor. To prevent excessively hot gas from reaching the compressor, the expansion valve (quench) (11) opens  to  allow  liquid  refrigerant  to  mix  with  the  hot  gas. l The  service  valves  (13)  are  provided  for  charging,  and  general  servicing  of  the  high  and  low  pressure sides  of  the  refrigerant  system. l The  pressure  switch  (low)  (14),  the  pressure  switch  (high)  (15),  and  the  pressure  relief  valve  (4)  are provided  to  protect  the  unit  from  damage  due  to  pressure  extremes. 1-12.   HEATING a.  HI  HEAT  mode.  When  the  mode  selector  switch  is  set  for  HI  HEAT  the  six  heating  elements,  located behind  the  evaporator  coil,  are  energized.  These  elements  are  protected  from  overheating-by  a  thermal  cutout switch.   Three   of   the   elements   are   thermostatically   controlled   by   the   temperature   control   thermostat,   and remaining  three  are  on  all  of  the  time. b.  LO  HEAT  mode.  When  the  mode  selector  switch  is  set  for  LO  HEAT,  only  the  three  thermostatically controlled  heating  elements  are  used. 1-7/(1-8  blank)

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business