4-22. FRESH AIR DAMPER AND ACTUATOR-Continued,
REMARKS
ACTION
LOCATION/ITEM
Service -
Continued)
1. Fresh Air
Ventilation
Dry cleaning solvent (P-D-680), used to
Damper
clean parts is potentially dangerous to
personnel and property. Avoid repeated
and prolonged skin contact. Do not
use near flame or excessive heat.
Carefully scrape away all adhesive
b.
from damper cover and opening,
and clean with dry cleaning solvent
Item 16, App. D).
Clean control cable wire and sheath
a.
B. Push-Pull
using dry cleaning solvent (Item 16,
Control
Cable
Slide control wire into sheath.
b.
Wipe off loose dirt using lint
a.
9 . Ventilation
free cloth (Item 9, App. D). For
Control
stubborn dirt, wash with warm soapy
Actuator
water using lint free cloth (Item
9, App. D) and rinse.
Repair
Straighten damper and cover if
a.
10. Fresh Air
possible. Replace if necessary.
Ventilation
Remove and replace cellular rubber
b.
Damper
seals on damper if necessary using
cellular rubber strips (Item 29,
hesive (Item 18, App. D).
Replace vent damper bearings as
c.
necessary.
Straighten out minor kinks and
11. Push-Pull
bends in control wire and sheath
Control
or replace as necessary.
Cable
Straighten if possible. Replace as
12. Ventilation
necessary.
Control
Actuator
4-39
|